Window Energy Ratings Explained: Reading the NFRC Label and ENERGY STAR

Window Energy Ratings Explained: Reading the NFRC Label and ENERGY STAR

U-factor, SHGC and the other numbers on a window label let you compare brands on equal terms. Here is what each one means and what ENERGY STAR requires in our climate zone.

Estimated Read Time:

Share:

Two new white double-hung windows with grids, seen from inside

When you shop for replacement windows, every quote and brochure throws numbers at you: U-factor 0.25, SHGC 0.28, “ENERGY STAR certified.” Those numbers are actually useful, because they let you compare windows from different brands on the same scale. You just need to know what each one means and which ones matter most where you live.

This guide explains the National Fenestration Rating Council (NFRC) label, what each rating measures, and the current ENERGY STAR requirements for the climate zone that covers Bucks and Montgomery counties.

What the NFRC label is

The NFRC label lets you compare the energy performance of windows, doors and skylights using the same set of ratings. According to the NFRC consumer guide, every NFRC-certified window has a label showing its ratings along with the manufacturer, model number and size, and the system is based on whole-product performance, meaning the ratings describe the full window, frame and all, not just the glass.

ENERGY STAR tells shoppers to look for the ENERGY STAR label for their climate zone next to the NFRC label on the glass, and to save both labels as documentation.

The five NFRC ratings, in plain English

U-factor: how well the window keeps heat in

The NFRC says U-factor measures how well a product keeps heat from escaping a room. Lower is better. NFRC gives a typical range of 0.20 to 1.20 for windows. A Department of Energy guide from Oak Ridge National Laboratory describes it as non-solar heat flow through both the glass and the frame. The NFRC consumer guide advises prioritizing a low U-factor in cold climates.

Do not confuse U-factor with R-value. The NFRC consumer guide points out that R-value rates insulation in walls, roofs and floors, where higher is better. With U-factor, lower is better.

Solar Heat Gain Coefficient (SHGC): how much of the sun’s heat gets in

SHGC measures how much solar heat a window lets in, on a scale from 0 to 1. NFRC explains that low numbers resist solar heat and high numbers allow it. Neither is “better” everywhere. The NFRC consumer guide notes that the best values depend on climate and which way the window faces. ENERGY STAR says colder climates tend to favor higher solar heat gain on south-facing windows, while warmer climates favor low solar heat gain on south-, east- and west-facing windows.

Visible Transmittance (VT): how much daylight comes through

VT measures how much visible light passes through the window, also on a scale from 0 to 1. Higher means more natural light. The NFRC consumer guide notes that higher VT can reduce reliance on electric lighting but has to be balanced against heat gain.

Air Leakage: how much air gets through the window itself

Air leakage measures how much outside air can enter through the window assembly. Lower is better. The NFRC consumer guide lists it as an optional rating, and notes that low air leakage also reduces drafts and street noise. ENERGY STAR requires windows to have an air leakage rating of 0.3 cubic feet per minute per square foot (cfm/ft²) or less.

Condensation Resistance: how well the window resists interior moisture

This optional rating measures a window’s ability to resist condensation on its interior surface, on a scale from 1 to 100. Higher is better. It is not a guarantee of a dry window. ENERGY STAR explains that water condenses on interior window surfaces when the surface temperature is below the dew point, and that even certified windows can have condensation in cold weather. Indoor humidity plays a big role. Our article on signs your windows need replacement explains the difference between condensation on the glass and fog between the panes.

Quick reference

Rating What it measures Better is
U-factor Heat escaping through the whole window Lower
SHGC Solar heat coming in Depends on climate and orientation
Visible Transmittance Daylight coming in Higher (if you want more light)
Air Leakage (optional) Air passing through the window assembly Lower
Condensation Resistance (optional) Resistance to interior condensation Higher

ENERGY STAR: what the label requires in our area

ENERGY STAR certifies windows by climate zone, so a window certified for one part of the country may not be certified for another. The current specification is ENERGY STAR Version 7.0 for residential windows, doors and skylights, effective October 23, 2023.

ENERGY STAR’s county-by-county climate zone list places Bucks, Montgomery, Chester, Delaware and Berks counties in the North-Central zone. Lehigh County, for comparison, falls in the Northern zone. If you live elsewhere, use ENERGY STAR’s climate zone finder to check.

Under Version 7.0, a window certified for the North-Central zone must meet:

  • U-factor: 0.25 or lower
  • SHGC: 0.40 or lower
  • Air leakage: 0.3 cfm/ft² or lower

For comparison, the Northern zone requires a U-factor of 0.22 or lower with an SHGC of 0.17 or higher, with some allowed trade-offs between the two. That is why a window line can carry different ENERGY STAR labels in different regions.

How much difference do efficient windows make?

ENERGY STAR states that replacing single-pane windows with ENERGY STAR certified windows lowers household energy bills by an average of up to 13 percent nationwide. Results vary by home, climate and the windows being replaced. ENERGY STAR also notes that low-E coatings used on efficient windows reduce fading by up to 75 percent.

Using the ratings when you compare quotes

  • Compare like with like. Make sure each quote lists the ratings for the same window style and glass package you are actually being offered.
  • Check U-factor closely. Our winters are cold, and the NFRC consumer guide says to prioritize a low U-factor in cold climates.
  • Think about SHGC by direction. A big west-facing window that overheats in summer may call for a different glass choice than a north-facing one.
  • Ask for air leakage if it is not on the label. Since it is optional on the NFRC label, not every product shows it.
  • Do not forget installation. The NFRC consumer guide warns that without proper installation, even the best windows may not perform as expected.

If you are comparing specific brands, our ProVia vs. Marvin windows comparison walks through two of the lines we offer.

Frequently asked questions

What is a good U-factor for windows in Bucks or Montgomery County?

Both counties are in ENERGY STAR’s North-Central zone, where Version 7.0 requires a U-factor of 0.25 or lower for certified windows. Lower is better.

Is a lower SHGC always better?

No. SHGC measures how much solar heat comes in. The right value depends on climate and which way the window faces. ENERGY STAR’s North-Central criteria call for an SHGC of 0.40 or lower.

What is the difference between U-factor and R-value?

Both describe insulating performance, but in opposite directions. Lower U-factor is better and is used for windows. Higher R-value is better and is used for insulation in walls, roofs and floors.

Why do some labels not show air leakage or condensation resistance?

Those two ratings are optional on the NFRC label. ENERGY STAR still requires certified windows to have air leakage of 0.3 cfm/ft² or less.